Fanuc Repairs
Refurbished Fanuc Amplifiers, Power Supplies & Motors
Here at gotronic ltd our engineers have the expertise to manage all aspects of Fanuc repairs to the Alpha product range. Our comprehensive range of product repairs covers Servo Amplifiers (SVM) and Spindle Amplifiers (SPM) to Power Supplies (PSM) in addition to a range of ‘Red Cap’ Servo Motors. We undertake comprehensive product diagnosis that allows us to identify and repair a wealth of issues. We’ve developed an innovative and fully-functional test rig that allows our engineers to efficiently program and run all aspects of any Fanuc system.
We stock all required parts and accessories at our offices. This enables us to complete all repairs in a quick turnaround time. We stock an extensive collection of refurbished amplifiers, power supplies and motors. These are ready for immediate dispatch. Click here to see our current stock list. Indeed, whether you need a replacement Fanuc Alpha Component, or complete repairs, we can help you.
FANUC Series 0-C Codes
Alarm no. | SVU,SVUC | Description | Code |
---|---|---|---|
309 Alarm 3 | - | pulse coder alarm error | OVC |
309 Alarm 4 | - | Pulse coder communication error alarm | |
400 Alarm1 Bit7 | - | Overheat alarm motor | |
414 Alarm1 Bit5 | - | Overload alarm | OVC |
414 Alarm1 Bit3 | 1 | DC link over-voltage alarm | HV |
414 Alarm1 Bit6 | 2 | Low control power voltage alarm | LV |
3 | Low DC link voltage | LVDC | |
414 Alarm1 Bit 2 | 4 | Regenerative discharge control circuit failure alarm | DCSW |
5 | Over-Regenerative discharge alarm | DCOH | |
414 Alarm1 Bit2 | 7 | Dynamic brake circuit failure alarm | DBRLY |
Alarm1 Bit6 | |||
414 Alarm1 Bit4 | 8 | L axis over-current alarm | HCL |
8. | L axis IPM alarm | IPML | |
9 | M axis over-current alarm | HCM | |
9. | M axis IPM alarm | IPMM | |
b | L, M axis over-current alarm | HCLM | |
b. | L, M axis IPM alarm | IPMLM | |
416 Alarm1 Bit1 | Feedback disconnected alarm | ||
417 | Invalid servo parameter setting alarm |
FANUC Series 15
Alarm no. | SVU,SVUC | Description | Code |
---|---|---|---|
SV001 | - | Overload alarm | OVC |
SV003 | 8 | L axis over-current alarm | HCL |
8. | L axis IPM alarm | IPML | |
9 | M axis over-current alarm | HCM | |
9. | M axis IPM alarm | IPMM | |
b | L, M axis over-current alarm | HCLM | |
b. | L, M axis IPM alarm | IPMLM | |
SV004 | 1 | DC link over-voltage alarm | HV |
SV005 | 4 | Regenerative discharge control cicuit failure alarm | DCSW |
5 | Over-Regenerative discharge alarm | DCOH | |
SV005 | 7 | Dynamic brake circuit failure alarm | DBRLY |
SV006 | |||
SV006 | 2 | Low contorl power voltage alarm | LV |
3 | Low DC link voltage | LVDC | |
SV015 | Feedback disconnected alarm | ||
SV023 | Overheat alarm | motor | |
SV027 | Invalid servo parameter setting alarm | ||
SV110 | pulse coder alarm error | ||
SV114 | Rotation speed data error alarm | ||
SV115 | Pulse coder communication error alarm | ||
SV117 | Current conversion error alarm |
FANUC Series 16,18,20
Alarm no. | SVU,SVUC | Description | Code |
---|---|---|---|
350 Alarm3 | - | pulse coder alarm error | |
350 Alarm4 bit6 | Rotation speed data error alarm | ||
350 Alarm4 bit6 | - | Pulse coder communication error alarm | |
400 Alarm1 bit7 | - | Overheat alarm (motor) | |
414 Alarm5 bit6 | Current conversion error alarm | ||
414 Alarm1 bit5 | - | Overload alarm | OVC |
414 Alarm1 bit3 | 1 | DC link over-voltage alarm | HV |
414 Alarm1 bit6 | 2 | Low control power voltage alarm | LV |
3 | Low DC link voltage | LVDC | |
414 Alarm1 bit 2 | 4 | Regenerative discharge control cicuit failure alarm | DCSW |
5 | Over-Regenerative discharge alarm | DCOH | |
414 Alarm5 bit5 | 7 | Dynamic brake circuit failure alarm | DBRLY |
414 Alarm1 bit4 | 8 | L axis over-current alarm | HCL |
8. | L axis IPM alarm | IPML | |
9 | M axis over-current alarm | HCM | |
9. | M axis IPM alarm | IPMM | |
b | L, M axis over-current alarm | HCLM | |
b. | L, M axis IPM alarm | IPMLM | |
416 Alarm1 bit1 | Feedback disconnected alarm | ||
417 | Invalid servo parameter setting alarm |
To find out how we can save you time and money, call us today on: 0121 557 3837, or click here to complete our online enquiry form.